Knowledgebase
MFJ Enterprises Inc. > Help Desk > Knowledgebase

1317/4103 Specifications

Solution
1317 specs:
Input voltage: 100-240 VAC (limits: 90-264 VAC)
Input frequency: 47 to 63 Hz (limits: 47-440 Hz)
Input current: 0.8A(rms) - 115 VAC; 0.6A(rms) - 230 VAC
Safety ground leakage current: 1.0A max@ 240 VAC, 50 Hz
Output voltage: 13.8 VDC (+-5% tolerance)

Output current: see rating chart

Output power range: 40 Watts maximum

Ripple: 1% peak to peak maximum

Over voltage protection: set at 112-132% of nominal

Over current protection: all outputs, short circuit conditions

Temperature coefficient: all outputs +-0.04% / C maximum

Transient response: max excursion of 4% or better.  recovering to 1% of final value within 500 uS after 25% step load change.

Operation temperature: 0 degrees C - +40 degrees C

Storage temperature: -40 degrees to +85 degrees C

Relative Humidity: 5% to 95% non-condensing

Derating: Derated from 100% at +40 degrees C linearly to 50% at 70 degrees C

Efficiency: 65% at full output

Hold-Up time: 5 Msec minimum

Line regulation: +- 0.2% maximum for any input voltage change between input voltage range.

Load regulation: +-5% variations from minimum to maximum output current.

Insulation resistance: 50 M ohm minimum from output to ground.

Inrush current: 15 Amps @115 VAC, or 30 Amps @230 VAC at 25 degrees C cold start.

Withstand voltage: 3000 VAC from input to output, 1500 VAC from output to ground.

Mean time between failure: 100,000 hours minimum at full load, at 25 degrees C ambient.

Emi requirements: Meets conduction limits of (a) FCC part 15, class B.  (b) CISPR 22.2.

Safety requirements: Meets or exceeds: (a) UL 1950; (b) CSA C22.2; (c) TUV EN60950; (d) IEC950.

Warranty: 1 year.
Article details