MFJ-815 Calibration

Solution
the pc board should already be labeled with the appropriate designations.  there four trimpots side by side, R201, R203, R205, R207.  they should be labeled HI FOR, LO FOR, HI REF, LO REF.  you will simply adjust each of these to a reference meter.
 
Richard C. Stubbs, Jr., KC5NSZ
MFJ Customer Services